Radio Manufacturers Service. Your Guarantee of Best Radio Service


• TONE   CONTROLS •
POTTED WAX-PAPER CONDENSER TYPES

Tone Controls

 

   PHILCO tone controls can be connected to the plate circuit of the first audio or output stage of any set. One side of the by-pass condensers contained in the unit is connected to the grounded housing.

 

TONE CONTROLS
Number of
Switch Points
Capacity Ranges Part No.
2 Point 1 - 0.0 Mfd. (open)
Point 2 - .01 Mfd.
03637

2

Point 1 - 0.0 Mfd. (open)
Point 2 - .02 Mfd.

04757
2 Point 1 - .01 Mfd.
Point 2 - .02 Mfd.
05153

2

Point 1 - .01 Mfd.
Point 2 - .015 Mfd.

30-4008
4 Point 1 - 0.0 Mfd. (open)
Point 2 - .015 Mfd.
Point 3 - .025 Mfd.
Point 4 - .035 Mfd.
04787
4 Point 1 - 0.0 Mfd. (open)
Point 2 - .015 Mfd.
Point 3 - .01 Mfd.
Point 4 - .01 Mfd.
4037-A